1.
Chinese Journal of School Health ; (12): 1871-1873, 2021.
Article in Chinese | WPRIM | ID: wpr-907081

ABSTRACT

Objective@#To investigate quality of short term eclectic psychological counseling services.@*Methods@#This study recruited 965 clients (4 261 sessions) at the university counseling center. The CORE-OM were implemented before and after the counseling service.@*Results@#Except crisis subscale, proportion of high scores over cut off points in well being, anxiety, depression, physical problems, trauma, relationships, general social functioning decreased significantly after counseling ( χ 2=32.91, 42.10 , 33.75, 11.81, 29.64, 10.82, 15.55, P <0.01); Except for harm toward other subscale, scores in subjective well being, problems/symptoms, life/social dysfunctions decreased significantly after counseling ( t =15.12, 28.85, 19.96, 5.88, P <0.01). Changes in CORE-OM score among 338 out of 640 participants achieved significant reliable change index.@*Conclusion@#Short term eclectic psychological counseling in higher educational setting helps alleviate psychological distress including anxiety, depression, relationship issues.

2.
Chinese Journal of Laboratory Medicine ; (12): 204-208, 2019.
Article in Chinese | WPRIM | ID: wpr-746269

ABSTRACT

Objective To prepare the trueness verification materials of C-reactive protein (CRP) and evaluate its homogeneity, stability and commutability. Methods The high and low CRP concentrations trueness verification materials were from patient leftover sera which were pooled, mixed thoroughly, filtered and aliquoted. The homogeneity, stability and commutability of these materials were evaluated according to CNAS(China National Accreditation Service for Conformity Assessment, CNAS)-GL29:2010 "Reference materials-General and statistical principles for certification (ISO Guide35:2006)"and the Clinical and Laboratory Standards Institute (CLSI) EP30A. The trueness verification materials were used to evaluate the commutability in 10 clinical CRP detection systems, using forty-five patients' leftover sera with different CRP concentration evaluated by Deming regression in EP30A of CLSI. Meanwhile, the commutability of dilution series of ERM DA-474/IFCC were evaluated using the same method. Results A total of two CRP concentration level trueness verification materials were prepared, with high and low concentration levels of 754 and 743 vials, 1 ml each, respectively. The preparation showed good homogeneity (F<F0.05(14,30);On the condition of room temperature, 2-8 ℃ and -80 ℃, these materials were stable for 7 days and 44 months respectively, the slope of the linear equation of | b1 | less than t0.95,n-2 · s(b1), there was no statistically significant difference between the slope and zero, the stability is satisfied. The materials and the dilution series of ERM-DA 474/IFCC also showed good commutability among patient sera in 10 systems. Conclusions The trueness verification materials of C-reactive protein (CRP) showed good homogeneity, stability and commutability. The dilution series ERM DA-474/IFCC also have good commutability. These provided experimental support for the value transfer and application of the trueness verification materials .

3.
Chinese Journal of Laboratory Medicine ; (12): 146-150, 2019.
Article in Chinese | WPRIM | ID: wpr-746260

ABSTRACT

Objective To explore the CRP harmonization by calibration using commutable trueness verification materials. Methods High and low level of CRP concentrations trueness verification materials(H and L) were prepared by Beijing center for clinical laboratories. Thesetrueness verification materials were diluted to 5 calibration points(5L, 4L+1H, 3L+2H, 1L+4H, 5H) by weighing method, respectively. These 5 points were used to calibrate four different brands of CRP detection system (Diasys, Leadman, Siemens and Roche) instead of the original procedure. Sera from 21 patients and the international standard ERM DA-474/IFCC were used to compare harmonization and trueness after calibration. Each sample above was measured twice. Results After calibration, the median of CV was reduced from 19.33% to 2.92% among 21 patient samples, less than the optimal CV based on biological variability (CV=10.6%). Compared with Desai, the slopes were closer to 1 from 0.90-1.09 to 0.93-0.96 after calibration. Meanwhile, if ERM-DA474/IFCC was used as the trueness verification materials, the absolute bias wasreduced from 3.08-11.07 mg/L to 0.52-2.97 mg/L which was close to theuncertainty of itself (2.5 mg/L). Conclusions Afterthe calibration which contained five linear concentration points of CRP trueness verification materials by weighing method, both harmonization and trueness of CRP were improved.

4.
Chinese Journal of Laboratory Medicine ; (12): 742-748, 2018.
Article in Chinese | WPRIM | ID: wpr-712204

ABSTRACT

Objective To value C-reactive protein ( CRP ) trueness verification materials and to perform the CRP trueness verification program in Beijing .Methods The CRP value of trueness verification materials were assigned by the international reference material ERM DA-474/IFCC, using 10 clinical routine detection systems at departments of clinical laboratory of Beijing Chaoyang and Luhe Hospital Affiliated to Capital Medical University .The calibration curves with 4 ERM DA-474/IFCC dilutions were established and used for value transfer for trueness verification materials of two levels .The uncertainty was also assessed during the process.Then, the trueness verification was performed in the EQA at Beijing Center for Clinical Laboratories ( BCCL ) among 42 clinical laboratories.The samples were distributed according to BCCL standard operating procedure .The Microsoft Excel 2007 and SPSS 17.0 were used to process the results and the function of efficiency ( En) was calculated to verify the difference between the value and the overall mean of all participating laboratories .Results The values and uncertainties of two trueness verification materials of CRP were (109.9 ±9.4) mg/L and (27.1 ±2.4) mg/L respectively.The results of trial application of two level trueness verification materials in the EQA at Beijing Center for Clinical Laboratories (BCCL) were satisfied.There were no significant difference between the transfer values from our study and the values from means of all laboratories in Beijing .The function of efficiency ( En ) was less than 1.Conclusions The valueswhich were established by using multiple detection platforms for CRP trueness verification materialswere accurate and the uncertainties were small .This method is a preferably method for CRP value assignment because there was no suitable reference method for CRP measurement till now .Thematerialswere suitable for the trueness verification program for clinical laboratories in Beijing .

5.
Chinese Journal of Laboratory Medicine ; (12): 922-929, 2016.
Article in Chinese | WPRIM | ID: wpr-508770

ABSTRACT

Objective To investigate the internal quality control ( IQC ) on clinical chemistry , clinical immunology and clinical hematology in mutual recognition laboratories in medical institutions in Beijing.Methods By means of questionnaire survey and on -site investigation, fresh frozen serum and whole blood samples with assigned values by reference method were measured to investigate the status of IQC on clinical chemistry , clinical immunology and clinical hematology in 142 mutual recognition laboratories in medical institutions of Beijing,and results were analyzed.Results 142 copies of questionnaireson clinical chemistry, clinical immunology and clinical hematology were send out and 120, 97, and 101 laboratories returned the questionnaires respectively .The information feedback rate was 84.5%, 68.3% and 71.1%respectively .All the questionnaires were effective .Questionnaires survey results showed that more than 50%laboratories set up quality control goals and the most of the goals were probability for error detection ( Ped) 95%, probability for false rejection(Pfr)5%;About 70% laboratories usecd the same quality control plan for different tests ;The most frequently used quality control rules are 12s/13s/22s.On-site investigation showed that ,take the results of clinical chemistry for example , based on the desirable biological variation and WS/T 403 -2012 , most of the tests can't meet the quality control goalsunder the existing quality controlcondition.Conclusion Clinical laboratories should consider their actual situations , assess their own qualitylevels that they can reach , set reasonable quality standards for themselves , and make appropriateindividualized quality control plan.

6.
Chinese Journal of Radiology ; (12)1994.
Article in Chinese | WPRIM | ID: wpr-677075

ABSTRACT

In this paper,we analysed the plain film of spine and CT bone mineral density(BMD)of lumbar vertebral body in 63 Chinese osteoporotic women. There are 29 and 34 cases with and without fracture respectively in these patients. The average value of BMD in the fracture group was markedly lower than that of the non fracture group (P=0.0006).We suggested that 95mg/cm ̄3 may be taken as an appropriate fracture threshold for Chinese elderly women, There were 18 and 45 cases with and without heterogenous calcification respectively in these patients.A significant difference of BMD was found between the two groups(P